Skip to Content
For emergencies: Call 1800 372 999
Gaeilge

Electronic business meters

How to take the reading of a business electronic meter?

To take the reading of a business electronic meter, look at the descriptions below.

Business meter-ABB Vision-Elster A1700 meter

ABB Vision/Elster A1700 meter

If your RM number is 548, 549, 645 or 647 you may have this meter. The RM number is at the bottom left hand side of the meter. This meter has an electronic display which changes every 9 seconds.

How to take a reading

  • Flat Rate & Time of Day Customers use screens 9, 10 & 11.
  • Maximum Demand Customers use screens 14, 16, 18, 19 & 20 If date of  last reset in screen 12 is not the current. month, readings cannot be taken as the meter has not been reset.
  • Record numbers left to right ignoring figures right of  decimal.
Meeting reading sheet PDF | 78 KB
Business meter-ABB-GEC PPM meter

ABB/GEC PPM meter

If your RM number is 545 or 667 you may have this meter type. The RM number is at the bottom left hand side of the meter. The meter has an automatic scrolling electronic display. The display changes every 6 secs illustrating 13 different information panels. Flat Rate & Time of Day - use Screens 11, 12 & 13.

How to take a reading:

  • Record numbers left to right. Ignore figures right of  decimal.
  • Maximum Demand - do not submit meter readings as the information required for billing is inaccessible from this meter. If you have any queries contact your Electricity Supplier.

Meeting reading sheet PDF | 80 KB
Business meter-Elster A1140-A1120 meter

Elster A1140/A1120 meter

If your RM number is 648, 651, 627, 553 or 551 this is the meter type you may have. The RM number is located at the bottom left hand side of the meter. This meter may have an auto scroll feature that changes screens automatically.  Press the button only if the meter has no auto scroll.

How to take a reading

  • 24 Hr reading (Total Day & Night) taken from screen CUM kWh
  • Day Reading is taken from screen TOU ACTIVE 2 kWh. The decimal point is not included in reading.
  • Night Reading will say TOU and Wattless Reading will say CUM
Meeting reading sheet PDF | 78 KB
Business meter-Iskra MT173 meter

Iskra MT173 meter

If your RM number is 649 or 552 this is the meter type you may have. The RM number is located at the bottom left hand side of the meter. This meter may have an auto scroll feature that changes screens automatically.

How to take a reading

  • Record the number left to right. If the meter has a decimal point, this is not included in the reading.
  • 1.8.2 = Day Reading  1.8.1 = Night Reading
  • 1.8.0 = 24 Hour Reading (Total Day & Night)
  • 5.8.0 = Wattless
Meeting reading sheet PDF | 153 KB

Can’t find what you’re looking for? We’re here to help.

Go to Customer support